USD-49 depth-integrating sampler

From Coastal Wiki
Revision as of 08:12, 4 June 2007 by Leovanrijn (talk | contribs)
Jump to: navigation, search

USD-49 depth-integrating sampler

The USD-49 is a depth integrating sampler. The sampler is lowered at a uniform rate from the water surface to the streambed, instantly reversed, and then raised again to the water surface. The sampler continues to take its sample throughout the time of submergence. At least one sample should be taken at each vertical selected in the cross-section of the stream. A clean bottle is used for each sample. The USD-49 sampler has a cast bronze streamlined body in which a round or square pint-bottle sample container is enclosed. The head of the sampler is hinged to permit access to the sample container (see Figure 1). The head of the sampler is drilled and tapped to receive the ¼-inch, 3/16-inch or 1/8-inch intake nozzle which points into the current for collecting the sample. The transit rate depends on the mean velocity in the vertical, the water depth and the nozzle diameter, as shown in Figure 2. The USD-49 is suitable for depth integration of streams less than about 5 m in which the velocities do not exceed 2 m/s. The sampler is manufactured by Rickly Hydrological company (www.rickly.com).

The depth-averaged concentration can be determined as

c=G/V

in which: G= dry mass of sediment (mg), V= volume of water sample (l).

The depth-integrated suspended sediment transport (in kg/m/s) can be determined as:

S= G h/(F T)    or as    S=c u h= (G/V) u h

in which: G= dry mass of sediment (mg), V= volume of sediment sample, including pores (m3),h= depth of sampled zone (m), u= depth-averaged velocity (m/s), F= area of nozzle (m2), T= sampling period (s).

The sampler cannot sample down to the stream bed surface. When the sampler touches the bed, the distance between the sample nozzle and the bed is about 0.1 m (see Figure 1). Thus, the depth of the sampled zone is about equal to the water depth minus 0.1 m. Another problem is the short sampling period at each specific point in the vertical. As a result concentration fluctuations are not averaged out and repeat samples are necessary.

Photographs and Figures

Fig. 1: USD-49 sampler
Fig. 2: Transit rate curve















References

INTER-AGENCY COMMITTEE on Water Resources, 1963. Determination of Fluvial Sediment Discharge Report no. 14, St. Anthony Falls Hydr. Lab., Minneapolis, USA.


See also

Other contributions of Leo van Rijn

articles with parts of the manual


External links

www.rickly.com([1]).


Crediting the authors

The main author of this article is {{{AuthorFullName}}}
Please note that others may also have edited the contents of this article.

Citation: {{{AuthorFullName}}} (2007): USD-49 depth-integrating sampler. Available from http://www.coastalwiki.org/wiki/USD-49_depth-integrating_sampler [accessed on 22-11-2024]

[[Category:Articles by {{{AuthorFullName}}}]]


The main author of this article is {{{AuthorFullName}}}
Please note that others may also have edited the contents of this article.

Citation: {{{AuthorFullName}}} (2007): USD-49 depth-integrating sampler. Available from http://www.coastalwiki.org/wiki/USD-49_depth-integrating_sampler [accessed on 22-11-2024]

[[Category:Articles by {{{AuthorFullName}}}]]