Difference between revisions of "In situ measurement of wet bulk density"

From Coastal Wiki
Jump to: navigation, search
Line 72: Line 72:
 
|AuthorFullName= Roberti, Hans
 
|AuthorFullName= Roberti, Hans
 
|AuthorName=Robertihans}}
 
|AuthorName=Robertihans}}
 +
 +
[[Category:Theme_9]]
 +
[[Category:Techniques and methods in coastal management]]
 +
[[Category:Geological processes, soil and minerals]]

Revision as of 16:14, 13 November 2007

IN-SITU MEASUREMENT OF WET BULK DENSITY

General aspects

In deposition and navigation depth studies of muddy areas the wet (bulk) density defined as the mass of the water-sediment mixture per unit volume is an important parameter.

The position of the surface of consolidated mudlayers can be determined by means of echo-sounding instruments. Good penetration can be obtained with 30 kHz-instruments, see Fig. 1A. Higher frequencies (210 KHz) do not have sufficient energy to penetrate into the bed.

Various methods are available to determine the wet bulk density: mechanical core sampler, acoustic probe, nuclear radiation probe, electric conductivity probe, vibration transducer probe, and pressure transducer probe. Electric conductivity probes and pressure transducer probes are not generally applicable. Electric conductivity probes are very sensitive to the fluid salinity which should be known beforehand. Pressure and vibration transducer probes can only be used in unconsolidated fluid muds (low density < 1200 kg/m3).


Mechanical core sampler

A basic requirement is undisturbed sampling of bed material.

Various mechanical core-samplers are available to take undisturbed bed material samples of the surface layers (upper 0.5 m of the bed). Most samplers can only be used during low velocity conditions to ensure vertical penetration of the bed.

After sampling, it is common practice to make slices by a machined ring of the same internal diameter as the core. The core content is extruded into the ring until it is full of the water-sediment mixture. A thin plate is then introduced between the ring and the core to isolate the sample.

As the core diameter is known and fixed and the slice thickness is fixed by the ring, the volume can be calculated. After weighing (and drying) of the sample, the wet and dry density can be determined.


Acoustic sensor

The principle is based on measuring the attenuation of the intensity of monochromatic ultra-sonic waves through the (fluid) mud layer.


Nuclear radiation sensor

The principle is based on measuring the attenuation or scattering of the radiation intensity through a water-sediment mixture.

References


Back to Chapters


External links

PDFs of the manual

9. IN-SITU MEASUREMENT OF WET BULK DENSITY (1,1 Mb)


Crediting the authors

The main author of this article is Rijn, Leo van
Please note that others may also have edited the contents of this article.

Citation: Rijn, Leo van (2007): In situ measurement of wet bulk density. Available from http://www.coastalwiki.org/wiki/In_situ_measurement_of_wet_bulk_density [accessed on 22-11-2024]


The main author of this article is Roberti, Hans
Please note that others may also have edited the contents of this article.

Citation: Roberti, Hans (2007): In situ measurement of wet bulk density. Available from http://www.coastalwiki.org/wiki/In_situ_measurement_of_wet_bulk_density [accessed on 22-11-2024]