==General principles of optical and acoustical instruments==
+
{{Review
 +
|name= Andrea Taramelli
 +
|AuthorID=20734
 +
}}
  
Optical and acoustical sampling methods enable the continuous and contactless measurement of sediment concentrations, which is an important advantage compared to the mechanical sampling methods. Although based on different physical phenomena, optical and acoustical sampling methods are very similar in a macroscopic sense. For both methods the measuring principles can be classified in (see Figure 1): transmission, scattering,
+
 
 +
This article is a summary of sub-section 5.6.4.1 of the [[Manual Sediment Transport Measurements in Rivers, Estuaries and Coastal Seas]] <ref>Rijn, L. C. van (1986). ''Manual sediment transport measurements''. Delft, The Netherlands: Delft Hydraulics Laboratory</ref>. This article describes the principles of three types of optical and acoustic instruments: transmission, scattering and transmission-scattering. Furthermore, the article describes the calibration, measuring range and advantages of [[remote sensing]] with optical and acoustical instruments.
 +
 
 +
==Measuring principles==
 +
[[Image:H5641figure1.jpg|thumb|250px|right|Figure 1: Basic principles]]
 +
Optical and acoustical sampling methods enable the continuous and contactless measurement of sediment concentrations, which is an important advantage compared to the mechanical sampling methods. Although based on different physical phenomena, optical and acoustical sampling methods are very similar in a macroscopic sense. For both methods the measuring principles can be classified in (see Figure 1): transmission, scattering,
 
transmission-scattering.
 
transmission-scattering.
  
'''''Transmission'''''
+
===Transmission===
The   source   and  detector   are  placed  in  an  opposite  direction  of  each other  at  a  distance 1.  The  sediment  particles  in  the measuring  volume reduce the beam intensity resulting in a reduced detector signal. The  relationship  between  the  detector  signal   (It)  and  the  sediment concentration (c)  is:
+
The source and  detector are  placed  in  an  opposite  direction  of  each other  at  a  distance 1.  The  sediment  particles  in  the measuring  volume reduce the beam intensity resulting in a reduced detector signal. The  relationship  between  the  detector  signal (I<sub>t</sub>)  and  the  sediment concentration (c)  is:
  
It=k<sub>1</sub> exp(-k<sub>2</sub> c)
+
<math>I_t=k_1\,e^{-k_2\,c}</math>
  
 
in which: k<sub>1</sub> = calibration constant depending on instrument characteristics, fluid properties and travel distance (l), k<sub>2</sub> = calibration constant depending on particle properties (size, shape), wave length and travel distance (l).
 
in which: k<sub>1</sub> = calibration constant depending on instrument characteristics, fluid properties and travel distance (l), k<sub>2</sub> = calibration constant depending on particle properties (size, shape), wave length and travel distance (l).
  
'''''Scattering'''''
+
===Scattering===
The source and detector are placed at an angle relative to each other (see Figure 1B). The detector receives a part of the radiation scattered by the sediment particles in the measuring volume. The  relationship  between  detector  signal  (Is)  and  sediment concentration (c) is:
+
The source and detector are placed at an angle relative to each other (see Figure 1B). The detector receives a part of the radiation scattered by the sediment particles in the measuring volume. The  relationship  between  detector  signal  (I<sub>s</sub>)  and  sediment concentration (c) is:
  
Is=k<sub>3</sub> c exp(-k<sub>2</sub> c)
+
<math>I_s=k_3\,c\,e^{-k_2\,c}</math>
  
 
in which: k<sub>3</sub> = calibration constant depending on instrument characteristics, fluid and particle properties (size, shape), wave length and travel distance (l).
 
in which: k<sub>3</sub> = calibration constant depending on instrument characteristics, fluid and particle properties (size, shape), wave length and travel distance (l).
 
An important disadvantage of the scattering method is the strong non-linearity of the relation between the detector signal and sediment concentration for large concentrations.
 
An important disadvantage of the scattering method is the strong non-linearity of the relation between the detector signal and sediment concentration for large concentrations.
  
'''''Transmission-scattering'''''
+
===Transmission-scattering===
 
This method is based on the combination of transmission and scattering, as shown in Figure 1C. If the travel distance for transmission and scattering is equal, a linear relationship for the ratio of both signals is obtained
 
This method is based on the combination of transmission and scattering, as shown in Figure 1C. If the travel distance for transmission and scattering is equal, a linear relationship for the ratio of both signals is obtained
  
 
+
<math>I=I_s\,/I_t\,=k_4\,c</math>
I=Is/It=k<sub>4</sub> c
 
  
 
in which: k<sub>4</sub> = calibration constant depending on instrument characteristics and particle properties.
 
in which: k<sub>4</sub> = calibration constant depending on instrument characteristics and particle properties.
Line 29: Line 36:
 
Important advantages are the absolute linearity between the output signal (I) and the sediment concentration, the independence of water colour and the reduced influence of fouling.
 
Important advantages are the absolute linearity between the output signal (I) and the sediment concentration, the independence of water colour and the reduced influence of fouling.
  
'''''Calibration'''''
+
==Calibration==
For all measuring principles an in-situ calibration for determining the constants is necessary, if possible under representative flow conditions covering the whole range of flow velocities and measuring positions (close to bed and water-surface). Regular calibration is required because the constants may change in time due to variations in temperature,  salinity and pollution.
+
For all measuring principles an [[in situ]] calibration for determining the constants is necessary, if possible under representative flow conditions covering the whole range of flow velocities and measuring positions (close to bed and water-surface). Regular calibration is required because the constants may change in time due to variations in temperature,  salinity and pollution.
 
In practice, the optical and acoustical sampling methods can only be used in combination with a mechanical sampling method to collect water-sediment samples for calibration. Usually, about 10% of the measurements should be used for calibration.
 
In practice, the optical and acoustical sampling methods can only be used in combination with a mechanical sampling method to collect water-sediment samples for calibration. Usually, about 10% of the measurements should be used for calibration.
The inaccuracy of field measurements may sometimes be rather large because of calibration problems (Kirby et al, 1981), particularly for optical samplers. The main problem is the lack of synchronity between the optical and mechanical sample collection. To minimize synchronity errors, the optical samplers should be calibrated bij measuring the silt concentration on board of the ship using a pre-collected water-silt sample.
+
The inaccuracy of field measurements may sometimes be rather large because of calibration problems (Kirby et al, 1981<ref name="kirb">Kirby,  R. and Parker,  W.R.,  1981. ''The  Behaviour  of  Cohesive  Sediment  in  the  inner  Bristol  Channel  and Severn Estuary''. Institute Oceanographic Sciences,  Report No.  117,  Taunton,  England</ref>), particularly for optical samplers. The main problem is the lack of synchronity between the optical and mechanical sample collection. To minimize synchronity errors, the optical samplers should be calibrated bij measuring the silt concentration on board of the ship using a pre-collected water-silt sample.
  
'''''Measuring range'''''
+
==Measuring range==
For an optimal sampling resolution the wave length and particle size must be of the same order of magnitude. Therefore the optical method is most suitable for silt particles (> 50 um). Laboratory experiments using the optical sampler, have shown that the addition of sand particles with a concentration equal to the silt concentration increased the output signal with about 10% ('''Der Kinderen, 1981'''). The upper  concentration  limit  for  optical  samplers  is about 25000 mg/1 ('''Kirby et al., 1981''').
+
For an optimal sampling resolution the wave length and particle size must be of the same order of magnitude. Therefore the optical method is most suitable for silt particles (> 50 um). Laboratory experiments using the optical sampler, have shown that the addition of sand particles with a concentration equal to the silt concentration increased the output signal with about 10% (Der Kinderen, 1981<ref>Der Kinderen,  W.J.G.J., 1980.  ''Silt Concentration Meters;  Evaluation'' (in Dutch).Delft Hydraulics Laboratory,  Report S453  I,  The Netherlands</ref>). The upper  concentration  limit  for  optical  samplers  is about 25000 mg/1 (Kirby et al., 1981<ref name="kirb"/>). The  acoustic method is  most suitable  for  sand particles  (>50 um).  The upper concentration limit is about 10000 mg/1.
The  acoustic method is  most suitable  for  sand particles  (>50 um).  The upper concentration limit is about 10000 mg/1.
 
  
'''''Advantages'''''
+
==Advantages==
An important advantage of optical and acoustical samplers is the continuous measurement of the suspended sediment concentration. In combination with a chart recorder for data collection a relatively long period (one month) can be sampled continuously and automatically. When there is very little variation of the silt concentrations in lateral direction of the cross-section, measurements at one point can be considered as representative for the whole cross-section. In that case the sensor can be fixed to a bridge pier or river side installation. The measuring location must be easily accessible for regular cleaning of the sensor and changing of batteries and chart records. Energy consumption and recorder maintenance can be minimized by using a switch system activating the sensor and recorder only for short periods (5 min) at preset intervals (1 hour) as reported by '''Brabben (1981)'''. Another advantage of the continuous signal is the possibility of determining continuous concentration profiles by raising the optical or acoustical sensor from the bed to the watersurface (rapid profile method, '''Kirby et al 1981'''). Using this latter method a complete concentration profile can be determined in one minute. To check the representativeness of these profiles, occasionally the concentration profile should also be determined by means of a number of point-integrated measurements. The horizontal variability can be determined by towing the sensor at a (monitored) depth below the water surface.
+
An important advantage of optical and acoustical samplers is the continuous measurement of the suspended sediment concentration. In combination with a chart recorder for data collection a relatively long period (one month) can be sampled continuously and automatically. When there is very little variation of the silt concentrations in lateral direction of the cross-section, measurements at one point can be considered as representative for the whole cross-section. In that case the sensor can be fixed to a bridge pier or river side installation. The measuring location must be easily accessible for regular cleaning of the sensor and changing of batteries and chart records. Energy consumption and recorder maintenance can be minimized by using a switch system activating the sensor and recorder only for short periods (5 min) at preset intervals (1 hour) as reported by Brabben (1981)<ref>Brabben, T.E., 1981. Use of Turbidity Monitor to assess Sediment Yields in East Java. ''Proc. Symp. Erosion and Sediment Transport Measurements'',  Florence,  Italy</ref>. Another advantage of the continuous signal is the possibility of determining continuous concentration profiles by raising the optical or acoustical sensor from the bed to the watersurface (rapid profile method, Kirby et al 1981<ref name="kirb"/>). Using this latter method a complete concentration profile can be determined in one minute. To check the representativeness of these profiles, occasionally the concentration profile should also be determined by means of a number of point-integrated measurements. The horizontal variability can be determined by towing the sensor at a (monitored) depth below the water surface.
 
Finally, it is remarked that both sampling methods can also be used to measure the instantaneous sediment concentration under wave conditions, provided the respons period is small  enough.
 
Finally, it is remarked that both sampling methods can also be used to measure the instantaneous sediment concentration under wave conditions, provided the respons period is small  enough.
  
 +
==See also==
 +
===Summaries of the manual===
 +
* [[Manual Sediment Transport Measurements in Rivers, Estuaries and Coastal Seas]]
 +
* Chapter 1: [[Introduction, problems and approaches in sediment transport measurements]]
 +
* Chapter 2:  [[Definitions, processes and models in morphology]]
 +
* Chapter 3: [[Principles, statistics and errors of measuring sediment transport]]
 +
* Chapter 4: [[Computation of sediment transport and presentation of results]]
 +
* Chapter 5: [[Measuring instruments for sediment transport]]
 +
* Chapter 6: [[Measuring instruments for particle size and fall velocity]]
 +
* Chapter 7: [[Measuring instruments for bed material sampling]]
 +
* Chapter 8: [[Laboratory and in situ analysis of samples]]
 +
* Chapter 9: [[In situ measurement of wet bulk density]]
 +
* Chapter 10: [[Instruments for bed level detection]]
 +
* Chapter 11: [[Argus video]]
 +
* Chapter 12: [[Measuring instruments for fluid velocity, pressure and wave height]]
  
==References==
+
===Other internal links===
 +
* [[Acoustic backscatter profiling sensors (ABS)]]
 +
* [[Acoustic point sensors (ASTM, UHCM, ADV)]]
 +
* [[Optical Laser diffraction instruments (LISST)]]
 +
* [[Optical backscatter point sensor (OBS)]]
 +
* [[Optical remote sensing]]
 +
* [[Currents and turbulence by acoustic methods]]
 +
* [[Use of X-band and HF radar in marine hydrography]]
  
'''Brabben, T.E., 1981'''. Use of Turbidity Monitor to assess Sediment Yields in East Java. Proc.Symp.  Erosion and Sediment Transport Measurements,  Florence,  Italy
 
  
'''Der Kinderen,  W.J.G.J., 1980'''.  Silt Concentration Meters;  Evaluation  (in Dutch).
 
Delft Hydraulics Laboratory,  Report S453  I,  The Netherlands
 
  
'''Der Kinderen, W.J.G.J., 1982'''. Silt Concentration Meters  (in Dutch). Delft Hydraulics Laboratory,  Report M1799  I, Delft,  The Netherlands
+
===Further reading===
 
 
'''Kirby,  R. and Parker,  W.R.,  1981'''.  The  Behaviour  of  Cohesive  Sediment  in  the  inner  Bristol  Channel  and Severn Estuary. Institute Oceanographic Sciences,  Report No.  117,  Taunton,  England
 
  
 +
Der Kinderen, W.J.G.J., 1982. ''Silt Concentration Meters'' (in Dutch). Delft Hydraulics Laboratory,  Report M1799  I, Delft,  The Netherlands
  
 +
==References==
 
<references/>
 
<references/>
  
==See also==
+
{{2Authors
 
+
|AuthorID1=13226
===Other contributions of Leo van Rijn===
+
|AuthorFullName1= Rijn, Leo van
 
+
|AuthorName1=Leovanrijn
====articles with parts of the manual====
+
|AuthorID2=12969
*[[Manual Sediment Transport Measurements in Rivers, Estuaries and Coastal Seas]]
+
|AuthorFullName2= Roberti, Hans
 
+
|AuthorName2=Robertihans}}
*[[INTRODUCTION, PROBLEMS AND APPROACHES IN SEDIMENT TRANSPORT MEASUREMENTS]]
 
*[[DEFINITIONS, PROCESSES AND MODELS IN MORPHOLOGY]]
 
*[[PRINCIPLES, STATISTICS AND ERRORS OF MEASURING SEDIMENT TRANSPORT]]
 
*[[COMPUTATION OF SEDIMENT TRANSPORT AND PRESENTATION OF RESULTS]]
 
*[[MEASURING INSTRUMENTS FOR SEDIMENT TRANSPORT]]
 
*[[MEASURING INSTRUMENTS FOR PARTICLE SIZE AND FALL VELOCITY]]
 
*[[MEASURING INSTRUMENTS FOR BED MATERIAL SAMPLING]]
 
*[[LABORATORY AND IN-SITU ANALYSIS OF SAMPLES]]
 
*[[IN-SITU MEASUREMENT OF WET BULK DENSITY]]
 
*[[INSTRUMENTS FOR BED LEVEL DETECTION]]
 
*[[ARGUS VIDEO]]
 
*[[MEASURING  INSTRUMENTS FOR FLUID VELOCITY, PRESSURE AND WAVE HEIGHT]]
 
 
 
 
 
==External links==
 
 
 
==Crediting the authors==
 
 
 
 
 
{{author
 
|AuthorID=13226
 
|AuthorName= Rijn, Leo van}}
 
 
 
  
{{author
+
[[Category:Coastal and marine observation and monitoring]]
|AuthorID=12969
+
[[Category:Observation of physical parameters]]
|AuthorName= Roberti, Hans}}
 

Latest revision as of 16:09, 26 October 2020



This article is a summary of sub-section 5.6.4.1 of the Manual Sediment Transport Measurements in Rivers, Estuaries and Coastal Seas [1]. This article describes the principles of three types of optical and acoustic instruments: transmission, scattering and transmission-scattering. Furthermore, the article describes the calibration, measuring range and advantages of remote sensing with optical and acoustical instruments.

Measuring principles

Figure 1: Basic principles

Optical and acoustical sampling methods enable the continuous and contactless measurement of sediment concentrations, which is an important advantage compared to the mechanical sampling methods. Although based on different physical phenomena, optical and acoustical sampling methods are very similar in a macroscopic sense. For both methods the measuring principles can be classified in (see Figure 1): transmission, scattering, transmission-scattering.

Transmission

The source and detector are placed in an opposite direction of each other at a distance 1. The sediment particles in the measuring volume reduce the beam intensity resulting in a reduced detector signal. The relationship between the detector signal (It) and the sediment concentration (c) is:

[math]I_t=k_1\,e^{-k_2\,c}[/math]

in which: k1 = calibration constant depending on instrument characteristics, fluid properties and travel distance (l), k2 = calibration constant depending on particle properties (size, shape), wave length and travel distance (l).

Scattering

The source and detector are placed at an angle relative to each other (see Figure 1B). The detector receives a part of the radiation scattered by the sediment particles in the measuring volume. The relationship between detector signal (Is) and sediment concentration (c) is:

[math]I_s=k_3\,c\,e^{-k_2\,c}[/math]

in which: k3 = calibration constant depending on instrument characteristics, fluid and particle properties (size, shape), wave length and travel distance (l). An important disadvantage of the scattering method is the strong non-linearity of the relation between the detector signal and sediment concentration for large concentrations.

Transmission-scattering

This method is based on the combination of transmission and scattering, as shown in Figure 1C. If the travel distance for transmission and scattering is equal, a linear relationship for the ratio of both signals is obtained

[math]I=I_s\,/I_t\,=k_4\,c[/math]

in which: k4 = calibration constant depending on instrument characteristics and particle properties.

Important advantages are the absolute linearity between the output signal (I) and the sediment concentration, the independence of water colour and the reduced influence of fouling.

Calibration

For all measuring principles an in situ calibration for determining the constants is necessary, if possible under representative flow conditions covering the whole range of flow velocities and measuring positions (close to bed and water-surface). Regular calibration is required because the constants may change in time due to variations in temperature, salinity and pollution. In practice, the optical and acoustical sampling methods can only be used in combination with a mechanical sampling method to collect water-sediment samples for calibration. Usually, about 10% of the measurements should be used for calibration. The inaccuracy of field measurements may sometimes be rather large because of calibration problems (Kirby et al, 1981[2]), particularly for optical samplers. The main problem is the lack of synchronity between the optical and mechanical sample collection. To minimize synchronity errors, the optical samplers should be calibrated bij measuring the silt concentration on board of the ship using a pre-collected water-silt sample.

Measuring range

For an optimal sampling resolution the wave length and particle size must be of the same order of magnitude. Therefore the optical method is most suitable for silt particles (> 50 um). Laboratory experiments using the optical sampler, have shown that the addition of sand particles with a concentration equal to the silt concentration increased the output signal with about 10% (Der Kinderen, 1981[3]). The upper concentration limit for optical samplers is about 25000 mg/1 (Kirby et al., 1981[2]). The acoustic method is most suitable for sand particles (>50 um). The upper concentration limit is about 10000 mg/1.

Advantages

An important advantage of optical and acoustical samplers is the continuous measurement of the suspended sediment concentration. In combination with a chart recorder for data collection a relatively long period (one month) can be sampled continuously and automatically. When there is very little variation of the silt concentrations in lateral direction of the cross-section, measurements at one point can be considered as representative for the whole cross-section. In that case the sensor can be fixed to a bridge pier or river side installation. The measuring location must be easily accessible for regular cleaning of the sensor and changing of batteries and chart records. Energy consumption and recorder maintenance can be minimized by using a switch system activating the sensor and recorder only for short periods (5 min) at preset intervals (1 hour) as reported by Brabben (1981)[4]. Another advantage of the continuous signal is the possibility of determining continuous concentration profiles by raising the optical or acoustical sensor from the bed to the watersurface (rapid profile method, Kirby et al 1981[2]). Using this latter method a complete concentration profile can be determined in one minute. To check the representativeness of these profiles, occasionally the concentration profile should also be determined by means of a number of point-integrated measurements. The horizontal variability can be determined by towing the sensor at a (monitored) depth below the water surface. Finally, it is remarked that both sampling methods can also be used to measure the instantaneous sediment concentration under wave conditions, provided the respons period is small enough.

See also

Summaries of the manual

Other internal links


Further reading

Der Kinderen, W.J.G.J., 1982. Silt Concentration Meters (in Dutch). Delft Hydraulics Laboratory, Report M1799 I, Delft, The Netherlands

References

  1. Rijn, L. C. van (1986). Manual sediment transport measurements. Delft, The Netherlands: Delft Hydraulics Laboratory
  2. 2.0 2.1 2.2 Kirby, R. and Parker, W.R., 1981. The Behaviour of Cohesive Sediment in the inner Bristol Channel and Severn Estuary. Institute Oceanographic Sciences, Report No. 117, Taunton, England
  3. Der Kinderen, W.J.G.J., 1980. Silt Concentration Meters; Evaluation (in Dutch).Delft Hydraulics Laboratory, Report S453 I, The Netherlands
  4. Brabben, T.E., 1981. Use of Turbidity Monitor to assess Sediment Yields in East Java. Proc. Symp. Erosion and Sediment Transport Measurements, Florence, Italy
The main authors of this article are Rijn, Leo van and Roberti, Hans
Please note that others may also have edited the contents of this article.

Citation: Rijn, Leo van; Roberti, Hans; (2020): General principles of optical and acoustical instruments. Available from http://www.coastalwiki.org/wiki/General_principles_of_optical_and_acoustical_instruments [accessed on 24-11-2024]