Difference between revisions of "Measuring instruments for estuaries"

From Coastal Wiki
Jump to: navigation, search
Line 1: Line 1:
 
The available instruments (and accuracies involved) for measuring:
 
The available instruments (and accuracies involved) for measuring:
  - bed load transport,
 
  
  - suspended sediment concentrations and transport rates,
+
* bed load transport,
 
+
* suspended sediment concentrations and transport rates,
  - particle sizes and fall velocities,
+
* particle sizes and fall velocities,
  
 
are presented in Tables 1, 2 and 3 below; order of preference is based on the overall sampling accuracy. Simple mechanical instruments such as the bottle-type and the trap-type samplers are not attractive because of the very short sampling times involved. Accuracy cannot be improved by increasing number of samples due to time-variation of sediment concentrations within the tidal cycle.  
 
are presented in Tables 1, 2 and 3 below; order of preference is based on the overall sampling accuracy. Simple mechanical instruments such as the bottle-type and the trap-type samplers are not attractive because of the very short sampling times involved. Accuracy cannot be improved by increasing number of samples due to time-variation of sediment concentrations within the tidal cycle.  

Revision as of 16:24, 29 May 2007

The available instruments (and accuracies involved) for measuring:

  • bed load transport,
  • suspended sediment concentrations and transport rates,
  • particle sizes and fall velocities,

are presented in Tables 1, 2 and 3 below; order of preference is based on the overall sampling accuracy. Simple mechanical instruments such as the bottle-type and the trap-type samplers are not attractive because of the very short sampling times involved. Accuracy cannot be improved by increasing number of samples due to time-variation of sediment concentrations within the tidal cycle. Point-samples should be taken over the entire water column in strong tidal flows as the sediments will be mixed over the water column by turbulent eddies. Data sampling can be confined to the bottom region in weak tidal flows. Flocculation often is a dominant process in muddy estuaries. The LISST-ST which is an in-situ Laser diffraction instrument in combination with a settling tube offers a powerful solution to measure particle sizes, concentrations and densities of the individual particles as well as the flocculated aggregates (low concentrations <150 mg/l) in on-line mode. This instrument (LISST-ST) is not yet suitable for long-term, stand-alone measurements due to insufficient robustness, relatively low concentration range (<150 mg/l) and biological fouling problems.

H533figure1.jpg
H533figure2.jpg

References


See also

Other contributions of Leo van Rijn

articles with parts of the manual

other articles

External links

Crediting the authors

The main author of this article is {{{AuthorFullName}}}
Please note that others may also have edited the contents of this article.

Citation: {{{AuthorFullName}}} (2007): Measuring instruments for estuaries. Available from http://www.coastalwiki.org/wiki/Measuring_instruments_for_estuaries [accessed on 22-11-2024]

[[Category:Articles by {{{AuthorFullName}}}]]


The main author of this article is {{{AuthorFullName}}}
Please note that others may also have edited the contents of this article.

Citation: {{{AuthorFullName}}} (2007): Measuring instruments for estuaries. Available from http://www.coastalwiki.org/wiki/Measuring_instruments_for_estuaries [accessed on 22-11-2024]

[[Category:Articles by {{{AuthorFullName}}}]]